Contact Site map Home
Polski Rosyjski Niemiecki

LABORATORY CHAMBER FURNACE TYPE FCF22

Type TYP FCF22
Max. temp. [°C] 1150
Chamber dimensions [mm] width x height x depth 290 x 220 x 350
Volume [dm³] 22
Overall dimensions [mm] width x height x depth 730 x 620 x 750
Power [kW] 3,3
Weight [kg] 80
Supply voltage [V~] 230
Heating up time (1000°C) [min] 50
print
a specification
sheet
make an inquiry about this product
If you have any questions please contact us:
tel. 32 47 07 495
tel./fax 32 47 07 502
e-mail: czylok@czylok.com.pl

Chamber furnaces are mainly used to carry out thermal processes requiring rapid rise in temperature at a uniformtemperature distribution. Furnaces have a short time to preheatgood temperature uniformity in the chamber and a long service life of heating elementsIt is possible to equip the furnace with a temperature programmer type M or temperature regulator type P.

TEMPERATURE PROGRAMMER TYPE M   TEMPERATURE REGULATOR TYPE P
 

One four-and two single displays allow easy reading of the actual temperature of the object and set parameters. With the ability to program a delayed start time as well as the holding time, ie. to maintain furnace temperature for a certain time, it is possible to automatically carry out a series of burnings unattended. This gives you the opportunity to work eg. during the night tariff for electricity or to heat-up the furnace to the required temperature ahead of time, avoiding unnecessary downtime. Has the ability to program the time (ie. speed) to reach the desired temperature. Characterized by a programmable 10 stages in each program of work, where the stage corresponds to the set temperature, the time to come to the temperature and time of annealing temperature setpoint. This enables the formation of burning curve for any given furnace with varying lengths of growth or fall of temperature over time.

 

Two four character displays allow easy reading of the actual temperature of the object and set parameters. With the ability to program a delayed start time as well as the holding time, ie. to maintain furnace temperature for a certain time, it is possible to automatically carry out a series of burnings unattended. This gives you the opportunity to work eg. during the night tariff for electricity or to heat-up the furnace to the required temperature ahead of time, avoiding unnecessary downtime.

 

List of additional equipment:
Additional portable temperature measurement system

Additional portable temperature measurement system

Basket for four crucibles and the basket handle. Baffle dimensions 30x30 mm, 25 mm depth; overall dimensions 90x80 mm, height 80 mm.

Basket for four crucibles and the basket handle. Baffle dimensions 30x30 mm, 25 mm depth; overall dimensions 90x80 mm, height 80 mm.

Catalyst excerpt

Catalyst excerpt

Ceramic shelf for the furnace chamber. Parts furnace chamber at half height. Available for FCF 12 and FCF 22.

Ceramic shelf for the furnace chamber. Parts furnace chamber at half height. Available for FCF 12 and FCF 22.

Chamber calibration. PCA accredited laboratory.

Chamber calibration. PCA accredited laboratory.

Computer program for visualization's recording and archiving time-temperature parameters of furnace operation.

Computer program for visualization's recording and archiving time-temperature parameters of furnace operation.

Computer set with a software

Computer set with a software

Connection of the protective gas supply. Installed on the door of the furnace, outer diameter 6mm.

Connection of the protective gas supply. Installed on the door of the furnace, outer diameter 6mm.

Cuvette with a holder. Holder's internal dimensions 150 x 100 x 200 mm  (WxHxD); vol 3 l, max temp. 1100° C.

Cuvette with a holder. Holder's internal dimensions 150 x 100 x 200 mm (WxHxD); vol 3 l, max temp. 1100° C.

Excerpt with a fan

Excerpt with a fan

Furnace stand with shelf

Furnace stand with shelf

Heat resistant gloves

Heat resistant gloves

Heat-resistant steel cuvette. The maximum use temperature up to 1100° C.

Heat-resistant steel cuvette. The maximum use temperature up to 1100° C.

Laboratory tongs

Laboratory tongs

Measurement calibration. PCA accredited laboratory.

Measurement calibration. PCA accredited laboratory.

Retort inset for muffle furnaces. Available for FCF 12S and FCF 22S. The maximum use temperature up to 1100° C.

Retort inset for muffle furnaces. Available for FCF 12S and FCF 22S. The maximum use temperature up to 1100° C.

Screen Recorder KD8. Touch screen 5.7", archiving data on the card up to 4 GB, 6 measurement inputs, visualization

Screen Recorder KD8. Touch screen 5.7", archiving data on the card up to 4 GB, 6 measurement inputs, visualization

Sight glass installed in the door of the furnace. Diameter 20 mm.

Sight glass installed in the door of the furnace. Diameter 20 mm.

Sound signaling completion of the program

Sound signaling completion of the program

Stand for six crucibles. 30mm hole diameter, 28mm depth, stand equipped with a handle base. The maximum use temperature up to 1100° C.

Stand for six crucibles. 30mm hole diameter, 28mm depth, stand equipped with a handle base. The maximum use temperature up to 1100° C.

Stand with canopy fitted to the outer dimensions of the furnace equipped with an exhaust fan and a lower shelf.

Stand with canopy fitted to the outer dimensions of the furnace equipped with an exhaust fan and a lower shelf.

Steel tray adapted to the dimensions of the furnace with a handle. The maximum use temperature up to 1100° C.

Steel tray adapted to the dimensions of the furnace with a handle. The maximum use temperature up to 1100° C.

Steel tray with holes, stand and tray holder. Adapted to the dimensions of the furnace. The maximum use temperature up to 1100° C.

Steel tray with holes, stand and tray holder. Adapted to the dimensions of the furnace. The maximum use temperature up to 1100° C.

Temperature sensor calibration. PCA accredited laboratory.

Temperature sensor calibration. PCA accredited laboratory.

Thermocouple connector (installed in the door of the furnace, acid-proof frame, max diameter 11mm).

Thermocouple connector (installed in the door of the furnace, acid-proof frame, max diameter 11mm).

Viewfinder provided with input from quartz glass. Diameter 25 mm.

Viewfinder provided with input from quartz glass. Diameter 25 mm.

<< back

See other products in the category: Chamber

Type Max. temp. Chamber dimensions [mm] Volume Overall dimensions [mm] Power Weight Supply voltage Heating up time (1000°C)
TYP [°C] width height depth [dm³] width height depth [kW] [kg] [V~] [min]
LABORATORY CHAMBER FURNACE TYPE FCF 2,5 FCF2,5 1150 140 100 180 2,5 500 360 520 0,9 25 230 50
LABORATORY CHAMBER FURNACE TYPE FCF 3,5H FCF3,5H 1350 150 110 210 3,5 530 795 500 2,8 60 230 50
LABORATORY CHAMBER FURNACE TYPE FCF 8 FCF8 1150 210 170 250 8 560 420 520 1,8 36 230 50
LABORATORY CHAMBER FURNACE TYPE FCF 14H FCF 14H 1350 240 210 270 14 580 890 920 3,5 70 230 60
LABORATORY CHAMBER FURNACE TYPE FCF22 FCF22 1150 290 220 350 22 730 620 750 3,3 80 230 50
LABORATORY CHAMBER FURNACE TYPE FCF 22H FCF22H 1300 290 220 350 22 780 680 830 5 88 400 50
LABORATORY CHAMBER FURNACE TYPE FCF 57 FCF 57 850 420 300 450 57 935 810 1070 6 140 400 -